main page
back to list
GMI-27B
Parameters and characteristics .

The oscillator pulse modulator tubes with the output power from 12 to 3500 kW and thyratrons with commutation current up to 5000 A are intended for operating in modulators of radio transmitters, medical instrumentation and accelerators of fundamental particles. They are also used as high frequency invertors in industrial units.

Type
Vf.
V
If.
A
Va. p.
kV
F max.
MHz
Poutput p.
kW
Overall dimensions
(LxD) mm
Mass
Kg
Powerful pulse triodes
-5
6,6
465
27
200
1200
450 180
12
-19-1
7,5
23
14
150
230
220 100
2,5
-24
6,6
465
27
200
800
441 180
12
-35
7,8
200
14
200
225
253 181
7,5
-35
7,8
200
14
200
225
338 167
9
-42
14,2
585
35
150
3500
440 233
30
-50
13,7
560
32
170
2000
420 210
18
Pulse tetrodes
-58
4,2
125
11
175
12
215 85
3
Pulse modulator tetrodes
Type
Vf.
V
If.
A
Va.
kV
Ia. p.
A
Overall dimensions
(LxD) mm
Mass
g
-7-2
26
5,6 - 6,4
22
52
186 120
800
-26
12,6
5,0 - 6,0
10
20
144 82
700
-27
12,6
5,0 - 6,0
10
20
144 94
750
-38-1
26
3,0 - 3,4
20
24
145 86
520


main page
back to list


Factory logo   Name (click=photo) Price, USD   Equivalents Description